Correlation to FVIII:C in two thrombin generation tests: TGA-CAT and INNOVANCE ETP

Marcus Ljungkvist
  • Marcus Ljungkvist
    Department of Translational Medicine & Centre for Thrombosis and Haemostasis, Malmö, Lund University, Sweden, Sweden | marcus.ljungkvist@med.lu.se

Abstract

            Abstract

Background and objectives

Several thrombin generation tests are available but few have been directly compared. Our primary aim was to investigate the correlation of two thrombin generation tests, thrombin generation assay-calibrated automated thrombogram (TGA-CAT) and INNOVANCE ETP, to factor VIII levels (FVIII:C) in a group of patients with hemophilia A.

The secondary aim was to investigate inter-laboratory variation for the TGA-CAT method.

Methods

Blood samples were taken from 45 patients with mild, moderate and severe hemophilia A. The TGA-CAT method was performed at both centers while the INNOVANCE ETP was only performed at the Stockholm center. Correlation between parameters was evaluated using Spearman´s rank correlation test. For determination of the TGA-CAT inter-laboratory variability Bland-Altman plots was used.

Results

The correlation for the INNOVANCE ETP and TGA-CAT methods with FVIII:C in persons with hemophilia (PWH) was r=0,701 and r=0,734 respectively.

The correlation between the two methods was r=0,546.

When dividing the study material into disease severity groups (mild, moderate and severe) based on FVIII levels, both methods fail to discriminate between them.

The variability of the TGA-CAT results performed at the two centers was reduced after normalization, before normalization 29% of values showed less than ±10% difference while after normalization the number increased to 41%.

Conclusions

Both methods correlate in an equal manner to FVIII:C in PWH but show a poor correlation to each other. The level of agreement for the TGA-CAT method was poor though slightly improved after normalization of data. Further improvement of standardization of these methods is warranted.

Keywords

thrombin generation test (TGT), thrombin generation assay-calibrated automated thrombogram (TGA-CAT), INNOVANCE ETP, platelet-poor plasma (PPP), platelet-rich plasma (PRP), test of agreement, FVIII:C, hemophilia

Full Text:

PDF
HTML
Submitted: 2017-08-02 11:19:46
Published: 2017-11-01 00:00:00
Search for citations in Google Scholar
Related articles: Google Scholar
Abstract views:
162

Views:
PDF
39
HTML
85

Article Metrics

Metrics Loading ...

Metrics powered by PLOS ALM


Copyright (c) 2017 Mediterranean Journal of Hematology and Infectious Diseases

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
 
© PAGEPress 2008-2017     -     PAGEPress is a registered trademark property of PAGEPress srl, Italy.     -     VAT: IT02125780185