COMPARATIVE STUDY ON THE MEASUREMENT OF LIVER T2* VALUES OF THALASSEMIA PATIENTS AND THE CLINICAL GRADING OF LIVER IRON CONCENTRATION BY DIFFERENT POST-PROCESSING SOFTWARE

MEASUREMENT OF LIVER T2* VALUES OF THALASSEMIA

Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.
Received: May 5, 2022
Accepted: September 25, 2022
Published: October 29, 2022
805
Views
459
Downloads
163
HTML

Authors

Objective: To explore the relationship between the liver T2* values of thalassemia patients measured by Circle Cardiovascular Imaging CVI42 (CVI42), CMRtools / Thalassemia Tools (CMRtools) and Excel spreadsheet (Excel), and the three software's accuracy in clinical grading of liver iron concentration (LIC). Methods: The liver T2* images thalassemia patients were imported into CVI42 and CMRtools to measure the T2* value. And the signal intensity (SI) of the T2* image, measured in the MR scanning equipment, was input into Excel to calculate T2* value. The relationship of the T2* values measured by the above three software were compared. And LIC clinical grading was performed on the three measured T2* value results, and the LIC (LICF) provided by FerriScan was used as the reference standard to compare the accuracy of the three grading results. Results: There was no statistical difference between the T2* values measured by CVI42, CMRtools and Excel (P>0.05), but there was a high degree of consistency between them (P<0.05), and there was a high linear positive correlation between the them (P<0.05). There was no statistical difference between the LIC grading results of CVI42 and CMRtools and the LICF grading results (P>0.05). There is a significant difference between the LIC grading results of Excel and the LICF grading results (P<0.05). Conclusion: The liver T2* values measured by CVI42, CMRtools and Excel are equivalent. However, CVI42 and CMRtools have better diagnostic accuracy for LIC clinical grade, while Excel has worse diagnostic accuracy.

Keywords: THALASSEMIA; lIVER T2 VALUE; 

Downloads

Download data is not yet available.

Citations

How to Cite



“COMPARATIVE STUDY ON THE MEASUREMENT OF LIVER T2* VALUES OF THALASSEMIA PATIENTS AND THE CLINICAL GRADING OF LIVER IRON CONCENTRATION BY DIFFERENT POST-PROCESSING SOFTWARE: MEASUREMENT OF LIVER T2* VALUES OF THALASSEMIA” (2022) Mediterranean Journal of Hematology and Infectious Diseases, 14(1), p. e2022072. doi:10.4084/MJHID.2022.072.